Gas Over Oil Control Cabinet Valve

gas over oil control cabinet valuve
The Cabinet has logic for.
1. Operating actuator when the line pressure is healthy (within the set limits)
2. Operating actuator for partial stroking.
3. Manual Reset function ie to close the actuator when line pressure falls either below or above set value and once closed the actuator does not operate even it line pressure is resumed, till the same is set manually.
System Pressure : 150 bar
Signal Pressure : 3 – 16 bar
certificates-2
read more…


Hi Low Pressure Cut Off Valve
ProductTypeDescriptionDownload
CB2
The Valve provides signal when pressure is within the two set limits.
The pneumatic signal is cut off when pressure is either above or below set limit
Pneumatic pressure 0 – 16 bar
Line pressure 0 – 15 bar
download



Torque Limiting Valve
ProductTypeDescriptionDownload
TLV4
The valve is cut off when pressure in the line increase above set pressure there by Limiting torque/ force which actuator/ cylinder can generate once the valve has to be set/ manually by external pilot.
Pressure Line : 10 – 100 bar
Pilot : 25 – 150 bar
Control : 5 – 16 bar

download



LINE Break Valve
ProductTypeDescriptionDownload
LBV2
Monitor healthiness of up and down stream pressure. Cut off the valve when any of the pressure fails. Once fail the valve can be reset manually.
Pressure Up stream : 50 – 150 bar
Pressure Down stream : 50 – 150 bar
Pressure Control pressure : 0 – 150 bar

download


3/2 Normally Closed Solenoid Valve
ProductTypeDescriptionDownload
30150 Subbase Port
30152 Threaded Port
Pressure 0 – 150 bar
Media gas, oil, air etc.
Ports : Threaded, sub base mounted
Body material SS 316/ Aluminium hard anodized

download


3/2 NC solenoid valve
ProductTypeDescriptionDownload
30150 Subbase Port
30152 Threaded Port
Pressure 0 – 150 bar
Media gas, oil, air, etc.
Ports : Sub base mounted. (No manual override).
Inter valve body
anodized

download



3/2 Roller Operated Valve
ProductTypeDescriptionDownload
DSA201-SU
Pressure 0 – 150 bar
Media gas, oil, air, etc.
Ports : threaded
Body material SS 316
download



3/2 Air Operated Valve
ProductTypeDescriptionDownload
3359 Air Operated
3383 Solenoid Operated
Pressure 0 – 150 bar
Media gas, oil, air, etc.
Media pressure 0 – 150 bar
Pilot pressure 5 – 150 bar
Pilot pressure minimum 5 bar or ≥ main
fluid pressure whichever is higher.
Pilot media Air/ Gas/ Oil
Body material SS 316
download



3/2, 5/2 Air Operated Spring Return
ProductTypeDescriptionDownload
7210
Pilot Pressure : 3.5 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Air Operated Spring Return with Manual Override
ProductTypeDescriptionDownload
7210M1
Pilot Pressure : 3.5 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Air Operated Spring Return with Lockable Manual Override
ProductTypeDescriptionDownload
7210M2
Pilot Pressure : 3.5 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Air Operated Spring Return
ProductTypeDescriptionDownload
7211
Pilot Pressure : 1.2 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Air Operated Spring Return with Manual Override
ProductTypeDescriptionDownload
7211M1
Pilot Pressure : 1.5 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Low Pilot Pressure Air Operated Spring Return Valve
ProductTypeDescriptionDownload
7232
Pilot Pressure : 1 - 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Low Pilot Pressure Air Operated Spring Return with Manual Override
ProductTypeDescriptionDownload
7232M1
Pilot Pressure : 1 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Low Pilot Pressure Air Operated Spring Return with Lockable Manual Override
ProductTypeDescriptionDownload
7232M2
Pilot Pressure : 1 – 16 bar
Suitable for Panel mounting
download



3/2, 5/2 Hand Operated Hand Return Valve
ProductTypeDescriptionDownload
7204
Suitable for Panel mounting
download



3/2, 5/2 Hand Operated Spring Return Valve
ProductTypeDescriptionDownload
7205
Suitable for Panel mounting
download



3/2, 5/2 Hand Operated Spring Return Valve with Lockable Manual Override
ProductTypeDescriptionDownload
7205M1
7205M2
Suitable for Panel mounting
download



3/2, 5/2 Air Operated Spring Return with Manual Reset Valve
ProductTypeDescriptionDownload
7210MR1
Valve does not operate with Pilot
Signal till set manually by pulling Knob. The valve
reset when pilot signal is removed.
Pilot Pressure : 3.5 – 16 bar
download



3/2, 5/2 Air Operated Spring Return Valve
ProductTypeDescriptionDownload
8210 / 9210
Main Pressure : 0-350 for 8 series valve 0-150 for 9 series valve Pilot Pressure : 10-150 for 9 series valve
10-350 for 8 series valve
download



3/2, 5/2 Air Operated Air Return Valve
ProductTypeDescriptionDownload
9211 / 8211
Main Pressure : 0-350 for 8 series valve 0-150 for 9 series valve Pilot Pressure : 10-150 for 9 series valve 10-350 for 8 series valve
download



3/2, 5/2 Air Operated Spring Return Valve
ProductTypeDescriptionDownload
9232 / 8232
Main Pressure : 0-350 for 8 series valve 0-150 for 9 series valve Pilot Pressure : 10-150 for 9 series valve 10-350 for 8 series valve
download



3/2, 5/2 Hand Operated Spring Return Valve
ProductTypeDescriptionDownload
8205/9205
Main Pressure : 0-350 for 8 series valve 0-150 for 9 series valve Pilot Pressure : 10-150 for 9 series valve 10-350 for 8 series valve
download



3/2, 5/2 Air Operated Spring Return Valve
ProductTypeDescriptionDownload
8204 / 9204
Main Pressure : 0-350 for 8 series valve 0-150 for 9 series valve Low Pilot Pressure: 5 – 160 bar
download