Product Range
Solenoid Valve
Angle Seat Valve
Pulse Jet Valve
Engineered Solutions for Critical Process Applications
Solenoid Coils
Special Valves
banner-h2-low-power-sol

Low Power Solenoid Valve

Valve is required to be operated using low solenoid power, e.g. field BUS, battery operated, solar panel operated, directly operated with PLC/ DCS output card Power consumption of 0.14 Watt at 12V DC is also the lowest, in a similar class, demonstrating the advanced technology being used by ROTEX in these valves.The valves are directly compatible to remote I/O terminals of various manufacturers like Simens, ABB, Turk, MTL and Stahl etc. for use in field BUS applications involving PROFIBUS DP-IS and PROFIBUS PA networks.

engineered valveengineered valve
Since there is a change in the valve construction, this group of Valves have been classified under a new range with a wide variety of solutions in 2 port, 3 port, and 5 port configuration in both Direct acting and pilot operated versions. Three different Solenoid constructions are available depending on the cabling needs :
DIN Plug (Type 65CR), suitable for flexible cable with a PG9 cable entry.
With Integral Terminal Box (Type 67 or 68) in epoxy coated Aluminium or (Type 67-CO or 68-CO) SS 316 construction suitable for armoured cable with gland (mainly for applications in Hydro carbon, Oil and Gas and Petrochemical industries, requiring high safety from Explosion Risk).

Rotex intrinsically safe Solenoid is certified as per IS/ EN/ IEC 60079-0 and 60079-18 for Ex ia IIC T6 standards ROTEX have approval for ATEX, INDIAN : CCOE, DGMS, INMETRO, GOST ROTEX also offers a complete range of NAMUR solenoid valve with Intrinsic Safety.
certificates-2

read more…


3/2 Normally Closed / Open
ProductModelPressure Range(Bar)Orifice Size (mm) Port Connection MediaApplicationDownload
P3007 (NC)
P3001 (NC )
P3009 (NO)
2 -8
2 -10
2 -8
6,10,16
1/4" TO 1" BSP, NPT
AAir, Inert Gases
Valve is
required
to be operated
using low
solenoid power,
e.g. field BUS
download



3/2 Universal
ProductModelPressure Range(Bar)Orifice Size (mm) Port Connection MediaApplicationDownload
P3005
P3008
P3012
P3006
P3017
0 – 8
0 – 8
0 – 8
0 – 10
0 – 10
5,6,10,16
1/4" TO 1" BSP, NPT
Air, Inert Gases
Valve is
required
to be operated
using low
solenoid power,
e.g. field BUS
download



5/2 Mono / Bistable
ProductModelPressure Range(Bar)Orifice Size (mm) Port Connection MediaApplicationDownload
P5001 (Mono)
P5003 (Mono)
P5006 (Bistable)
2 -10
2 -10
2 -10
6,12,25
1/4" TO 1" BSP, NPT
Air, Inert Gases,
Water, Oil
Valve is
required to be
operated using
low solenoid
power, e.g.
field BUS
download