Common Solenoid Valve Problems and How to Fix Them

20 Common Solenoid Valve Problems and How to Fix Them

Solenoid valves are the backbone of modern automation. They regulate air, water, oil, or gas flow in everything from process plants to packaging systems. But even the most reliable industrial solenoid valve can fail over time — not because of design flaws, but due to improper installation, poor air quality, wiring issues, or overlooked maintenance.

For OEMs, plant engineers, and system integrators, understanding solenoid valve problems and knowing how to troubleshoot solenoid valves effectively can prevent downtime, reduce maintenance costs, and increase equipment life.

In this in-depth guide, we’ll walk through the 20 most common solenoid valve problems, their root causes, fixes, and preventive measures. These are based on decades of field experience at Rotex Automation, where our engineers have diagnosed thousands of valve-related failures in industrial plants across sectors like oil & gas, power, pharma, and water treatment.

Understanding How Solenoid Valves Work

Before troubleshooting, it’s vital to recall how a solenoid valve operates. A solenoid valve converts electrical energy into mechanical motion. When electrical current passes through the solenoid coil, it creates a magnetic field that pulls a plunger, opening or closing the valve orifice to control media flow.

The main types include:

  • 1. Direct-acting solenoid valves: Suitable for small flow, low pressure, or zero-pressure applications.
  • 2. Pilot-operated solenoid valves: Handle higher flow and pressure by using system pressure to assist operation.
  • 3. Semi-direct acting valves: Combine both for medium pressure systems

When something goes wrong in this sequence — electrical signal, magnetic actuation, or mechanical movement — the result is a solenoid valve failure.

Common Causes of Pneumatic System Failures

At Rotex, we’ve identified several recurring causes of pneumatic breakdowns across multiple industries:

Troubleshooting Table
Major Complaint Root Cause Impact
Leakages and broken pneumatic lines Damaged fittings or incorrect installation Pressure loss and actuator malfunction
Solenoid valve failures Coil burnout, contamination, or worn seals Complete stoppage of control system
Relay, switch, or PLC output failure Electrical faults or overload Solenoid valve not energizing
Actuator corrosion Moisture ingress or poor air quality Sticking or sluggish actuator operation
Air contamination Dust, oil, or rust particles Clogging of valve orifices and seals
Moisture in compressed air Ineffective dryers or filters Internal corrosion and freezing issues

These issues account for nearly 80% of pneumatic equipment breakdowns observed by our service engineers.

20 Common Solenoid Valve Problems and How to Fix Them

1Solenoid Valve Not Opening

Symptoms:
No air or fluid flow even when the coil is energized.
Possible Causes:
  • No voltage reaching the coil
  • Burnt coil
  • Plunger stuck due to rust or dirt
  • Pressure differential too low (in pilot valves)
Fix:
  • Verify electrical supply using a multimeter
  • Check continuity of the coil
  • Clean or replace the internal parts if jammed
  • Ensure system pressure meets minimum requirements

2Solenoid Valve Not Closing

Symptoms:
Fluid or air continues to flow when valve should be shut.
Causes:
  • Damaged diaphragm or plunger seal
  • Debris preventing closure
  • Residual pressure in exhaust port
Fix:
  • Clean valve seat and orifice
  • Replace worn seals
  • Check exhaust path for blockage

3Coil Burnout

Symptoms:
No magnetic pull or burnt smell.
Causes:
  • Overvoltage or wrong coil rating
  • Continuous energization (100% duty cycle overload)
  • High ambient temperature
Fix:
  • Replace with correct voltage coil (e.g., 24V DC solenoid valve coil)
  • Use low-power or continuous-duty rated coils
  • Improve ventilation around valve

4Buzzing or Humming Noise

Causes:
  • AC coil magnet vibration
  • Damaged shading ring
Fix:
  • Replace coil
  • For DC systems, switch to DC solenoid valves to reduce vibration

5Intermittent Operation

Symptoms:
Valve opens/closes inconsistently.
Causes:
  • Loose electrical connections
  • Inconsistent signal from PLC or relay
Fix:
  • Tighten terminals and recheck PLC output
  • Add surge suppressor or LED connector for feedback

6Leakage Through Exhaust Port

Causes:
  • Worn spool or O-rings
  • Internal contamination
Fix:
  • Replace O-rings or spool seals
  • Flush valve with clean, dry compressed air

7Manual Override Malfunction

Causes:
Damaged button or spring
Fix:
  • Replace manual override assembly

8Slow Response or Delay

Causes:
  • Low voltage supply
  • Sticky plunger due to dirt or oil
  • Moisture in system
Fix:
  • Maintain rated voltage
  • Clean moving components
  • Ensure proper filtration and dryers

9Excessive Heat Generation

Causes:
  • Overvoltage
  • High ambient temperature
  • Coil operating continuously
Fix:
  • Use correct coil voltage
  • Switch to low-power solenoid valve options
  • Provide adequate cooling

10Contaminated Air Supply

Causes:
Oil, dirt, or rust from compressor lines.
Fix:
  • Install proper air filter and water separator
  • Maintain regular air dryer service

11Actuator Fails to Operate

Causes:
  • Valve not switching ports
  • Leakage in supply line
Fix:
  • Inspect pneumatic solenoid valve for switching function
  • Check actuator for internal corrosion or air loss

12Water or Moisture Inside Coil Housing

Fix:
  • Use weather-proof (IP65+) or flameproof enclosure
  • Seal cable entries with glands

13Valve Sticking in One Position

Causes:
  • Corrosion or foreign material buildup
  • Worn guide bush
Fix:
  • Clean valve internals
  • Replace damaged components

14Electrical Short Circuit

Causes:
  • Moisture ingress
  • Damaged insulation
Fix:
  • Inspect connectors
  • Replace damaged wires or use sealed connectors

15Low Flow or Pressure Drop

Causes:
  • Undersized valve
  • Blocked filter or orifice
Fix:
  • Recalculate flow coefficient (Cv) for proper sizing
  • Clean or replace filter

16Air Leakage Around Fittings

Causes:
  • Improperly tightened threads
  • Damaged seals or PTFE tape
Fix:
  • Reseal with Teflon tape
  • Replace fittings

17Valve Fails During Start-up

Causes:
Incorrect wiring or polarity
Fix:
  • Check electrical polarity for DC solenoid valves
  • Ensure proper grounding

18Frequent Valve Failures in Harsh Environments

Fix:
  • Switch to stainless steel body (SS316)
  • Use flameproof solenoid valves for hazardous zones

19PLC Output Board Damage Due to Coil Feedback

Fix:
  • Use flyback diodes or surge suppressors
  • Install LED connectors with built-in suppression

20Reduced Life Due to Improper Maintenance

Fix:
  • Establish periodic preventive maintenance
  • Replace worn seals before breakdown occurs

How to Troubleshoot Pneumatic Solenoid Valves — A Step-by-Step Checklist

Step Action Tools Required Purpose
1
Check power supply and polarity Multimeter Ensure correct voltage
2
Inspect coil continuity Ohmmeter Detect burnt coils
3
Verify air quality Filter/regulator Prevent contamination
4
Check valve operation manually Override button Confirm mechanical function
5
Clean or replace seals Spanner, air gun Restore tight sealing
6
Test system under load Pressure gauge Validate pressure and flow

Preventive Solenoid Valve Maintenance Tips

  • 1. Use clean, dry, filtered air — always install a filter regulator unit before the solenoid valve.
  • 2. Avoid over-tightening fittings to prevent cracks.
  • 3. Keep electrical connections dry with sealed glands.
  • 4. Follow coil duty cycles — use continuous-duty rated coils for long energization.
  • 5. Inspect and clean valve internals quarterly in critical operations.
  • 6. Document all maintenance actions for future reference.

Expert Insight: Why Most Pneumatic Failures Are Avoidable

Rotex field data shows that over 70% of solenoid valve failures are not product defects — they’re caused by air contamination, poor installation, or coil misselection. Regular checks on air quality, system pressure, and voltage can eliminate most downtime incidents.

Rotex’s Engineering Advantage

With 58+ years of innovation, Rotex provides engineer-designed solenoid valves built to minimize these failures.

Our Key Features:

● Low-Power Coils that reduce heat buildup and energy use.

● LED Diagnostic Indicators for quick visual troubleshooting.

● Actuator Life Enhancer to block moisture ingress.

● Modular Valve Manifolds (MVM) that reduce leak points by up to 70%.

● Intrinsically Safe and SIL3-rated Designs for high-reliability applications.

These engineering solutions empower OEMs and end-users to build smarter, safer, and more maintainable pneumatic systems.

💡

Pro Tip Box: Quick Fix Guide

Problem Quick Fix Long-Term Solution
Valve not opening Check power & coil continuity Replace coil or clean plunger
Air leakage Inspect fittings Replace O-rings and reseal
Coil overheating Check voltage & duty cycle Use low-power coil
Erratic operation Verify PLC output Install surge suppressor
Moisture ingress Seal cable entries Use IP67 housing

Conclusion

Most solenoid valve issues stem from improper maintenance or system design rather than product quality. By addressing air contamination, moisture ingress, electrical miswiring, and overvoltage conditions, engineers can extend equipment life dramatically.

Rotex Automation’s engineering team works closely with OEMs and process engineers worldwide to design durable, field-tested solenoid valves that perform reliably even in the harshest environments.

If your plant is facing frequent pneumatic solenoid valve failures or unexplained downtime contact Rotex to consult with our experts.

We’ll help you identify root causes, improve your air system reliability, and optimize performance with the right valve selection and maintenance strategy.

Still unsure what’s causing your pneumatic breakdowns?

Let our experts help you troubleshoot and select the right solution.